RANGE of CHARGING DEVICES type RKZ IZ for STARTER BATTERIES



Basic Technical parameters:

Types of RKZ I-Z
 
12/10 12/20 24/10 24/15 24/20 12;24/15
RatedMainsVoltage
Frequency
 
220V/50
Hz±10%
220V/50
Hz±10%
220V/50
Hz±10%
220V/50
Hz±10%
220V/50
Hz±10%
220V/50
Hz±10%
Output voltage -stabilized
 
14.4V±1%

14.41%

28.8V±1%

28.8V±2%

28.8V±1%

14.4V28.8V±1%

Output current max
 
10 А

20 А

10 А

15 А

20 А

15 А

Battery Capacity for charging not exceeding - 10 h 36÷85 Ah 85÷180 Ah 36÷85 Ah 55÷140 Ah 85÷180 Ah 55÷140 Ah
   
- Load characteristics IU stabilized ,DIN 41773
- Protection Class I
- Protection Degree IР 20
- Dimensions: lenght 280 mm
width 156 mm
height 190 mm
- Weight < 7 кg







RANGE OF CHARGING DEVICES FOR TRACTION BATTERIES



PROVIDES:
  • Optimal automatic charging with regard to fast performance, with stabilized charging characteristics;
  • Rectifying charging with pulsating reverse current, guaranteeing desulphatization and maintaining undercharging for an unlimited period of time;
  • Prevention from intense gassing, boiling and electrolyte heating;
  • Transformer and power elements protection;
  • Saving of electric energy, time and money;
  • A 24 month guarantee;
  • Guaranteed servicing.

Advantages of EPK M “PULSAR” and “ElPulsKar” devices

FUNCTIONAL POSSIBILITIES AND KINDS OF PROTECTIONS:
Stabilized charging characteristics according to DIN 41773, ensuring:

  • Optimum battery mass formation as to speed;
  • Charging modes automatic change;
  • Retarding the process of sulphurization and desulphurization of old batteries;
  • Electric energy saving;
  • Reverse pulse charging current;
  • Preventing Electrolyte stratification;
  • Allowing desulphurization and avoiding battery overcharging and overheating;
  • Selecting the electric current for the equalizing charge in dependence on battery capacity, avoiding electrolyte overheating and boiling over;
  • Preserving Stand-by mode for continuous storage of the accumulator batteries and equalizing charge of the cells (adapted to the AB condition);
  • Prolonging battery’s life and full usage of the cycles number;

PROTECTIONS:

  • Against battery back switching;
  • Against short circuit at the outlet;
  • Thermal protection of the transformer and power elements.

ОPTIONS:

  • Тemperature control of Battery Being Charged;
  • Digital measurements of initial parameters;
  • Microprocessor control for adjustment and indication;



BASIC TECHNICAL PARAMETERS OF A RANGE OF RECTIFIERS OF "PULSAR" ЕPK XX/XXM and “ElPulsKar XX/XXX-XXX” TYPE




         



Remark:
All the output charge parameters are stabilized.
The devices are with 24 months guarantee term.
The company fulfills special orders under coordinated technical requirements.




STARTER-CHARGING RECTIFIER “SZ 12; 24/500”


DETERMINATION:


The starter-charging rectifier SZ 12; 24/500 is designed for starting of cars and cargo tracks with constant current feeding 12V or 24V with capacity of the accumulator batteries up to 500Ah. Besides than the rectifier can charge.

SZ 12;24V/500 - high-frequency inverter rectifiers.

BASIC TECHNICAL PARAMETERS

1. Input Voltage - 3x380V±10%,50Hz±10%
2. Nominal output Voltage - 12V; 24V
3. Maximum current by starting - 500А
4. Nominal charge current - 30А
5. Maximum Voltage in Start regime - 12V; 24V ±2%
6. Charging tension - 14V; 28V ±2%
7. Charging tension stabilization - ± 2%
8. Work regimes
- START - interrupted: work 30 s; pause–4 min.
- CHARGE - interrupted, for batteries up to 500Ah.
9. Electro safety - I
10. Protection degree - IP21
11. Work temperature: - ( -40º ÷ +40ºC)
12. Mechanical construction - mobile
13. Dimensions Height Width Depth - 420x310x155 mm.

STRUCTURE AND WORKING

The start – charging rectifier SZ 12; 24/500 is high-frequency inverter rectifiers with two tension ranges: 12V and 24V.

The rectifier is made in mobile construction.

WORK REGIMES

1.”Start” regime
Rectifier works in this regime when switch “START/CHARGE” is putted in position “START”. Maximum output tension of the rectifier is 12/24V ±2%, maximum current – 500A.

2. “Charge” regime